Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Pathol ; 76(2): 82-97, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36600633

RESUMO

Historically, heavy metal measurement and interpretation has been a highly specialised area performed only in a handful of centres within the UK. However, recent years have seen a move to more local testing due to the repatriation of referred work into pathology networks and the increased availability of inductively coupled plasma mass spectrometry technology. While management of significant poisoning is still overseen by tertiary care poisoning specialists, management of milder cases may be undertaken locally.Non-specialist clinical scientists and clinicians need to know when heavy metal testing is appropriate, which samples are required (and any specific requirements around collection) and how to interpret and act on the results.This Best Practice article provides guidance on the investigation and monitoring of the toxic elements most frequently encountered in general medical practice; lead, mercury and arsenic. It is intended as a reference guide for the non-specialist and as a comprehensive summary for clinical toxicologists and clinical scientists.


Assuntos
Arsênio , Mercúrio , Metais Pesados , Humanos , Intoxicação por Metais Pesados/diagnóstico , Intoxicação por Metais Pesados/terapia , Metais Pesados/análise , Arsênio/análise , Mercúrio/análise , Monitoramento Ambiental
2.
BMJ ; 378: e071230, 2022 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-36215226

RESUMO

OBJECTIVE: To determine the effect of population level implementation of a test-and-treat approach to correction of suboptimal vitamin D status (25-hydroxyvitamin D (25(OH)D) <75 nmol/L) on risk of all cause acute respiratory tract infection and covid 19. DESIGN: Phase 3 open label randomised controlled trial. SETTING: United Kingdom. PARTICIPANTS: 6200 people aged ≥16 years who were not taking vitamin D supplements at baseline. INTERVENTIONS: Offer of a postal finger prick test of blood 25(OH)D concentration with provision of a six month supply of lower dose vitamin D (800 IU/day, n=1550) or higher dose vitamin D (3200 IU/day, n=1550) to those with blood 25(OH)D concentration <75 nmol/L, compared with no offer of testing or supplementation (n=3100). Follow-up was for six months. MAIN OUTCOME MEASURES: The primary outcome was the proportion of participants with at least one swab test or doctor confirmed acute respiratory tract infection of any cause. A secondary outcome was the proportion of participants with swab test confirmed covid-19. Logistic regression was used to calculate odds ratios and associated 95% confidence intervals. The primary analysis was conducted by intention to treat. RESULTS: Of 3100 participants offered a vitamin D test, 2958 (95.4%) accepted and 2674 (86.3%) had 25(OH)D concentrations <75 nmol/L and received vitamin D supplements (n=1328 lower dose, n=1346 higher dose). Compared with 136/2949 (4.6%) participants in the no offer group, at least one acute respiratory tract infection of any cause occurred in 87/1515 (5.7%) in the lower dose group (odds ratio 1.26, 95% confidence interval 0.96 to 1.66) and 76/1515 (5.0%) in the higher dose group (1.09, 0.82 to 1.46). Compared with 78/2949 (2.6%) participants in the no offer group, 55/1515 (3.6%) developed covid-19 in the lower dose group (1.39, 0.98 to 1.97) and 45/1515 (3.0%) in the higher dose group (1.13, 0.78 to 1.63). CONCLUSIONS: Among people aged 16 years and older with a high baseline prevalence of suboptimal vitamin D status, implementation of a population level test-and-treat approach to vitamin D supplementation was not associated with a reduction in risk of all cause acute respiratory tract infection or covid-19. TRIAL REGISTRATION: ClinicalTrials.gov NCT04579640.


Assuntos
COVID-19 , Infecções Respiratórias , Deficiência de Vitamina D , COVID-19/prevenção & controle , Colecalciferol , Suplementos Nutricionais , Método Duplo-Cego , Humanos , Infecções Respiratórias/tratamento farmacológico , Infecções Respiratórias/epidemiologia , Infecções Respiratórias/prevenção & controle , Vitamina D/uso terapêutico , Deficiência de Vitamina D/diagnóstico , Deficiência de Vitamina D/tratamento farmacológico , Vitaminas/uso terapêutico
3.
Ann Clin Biochem ; 53(Pt 4): 477-84, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26290514

RESUMO

BACKGROUND: Infliximab, a monoclonal antibody directed against tumour necrosis factor, is widely used in the treatment of chronic inflammatory conditions including Crohn's disease and rheumatoid arthritis. Its use is limited by development of anti-infliximab antibodies, which can lead to loss of therapeutic efficacy. Serum infliximab and anti-infliximab antibody measurements have recently become routinely available in the UK. The study aimed to assess the clinical utility of antibodies as an adjunct to trough infliximab. METHODS: Serum trough infliximab was measured in 201 samples from 108 gastroenterology and rheumatology patients on maintenance infliximab therapy. Results were correlated with C-reactive protein concentrations. Total anti-infliximab antibodies were measured in 164 samples. RESULTS: The median (25th-75th percentile) trough infliximab was 3.7 µg/mL (1.2-5.2 µg/mL) and 23% of samples had a concentration ≤1 µg/mL. A notable proportion had positive anti-infliximab antibodies: 84/164 (51%), which subdivided to 85% and 28% with infliximab ≤1 and >1 µg/mL, respectively.Serum C-reactive protein was found to be significantly higher where infliximab was ≤1 compared to >1 µg/mL (10 mg/L [<5-24 mg/L] vs. <5 mg/L [<5-8 mg/L], P < 0.01), although a strict correlation was not observed. The relationship between trough infliximab and C-reactive protein differed depending on antibody status and there was no association between C-reactive protein and the presence or absence of antibodies. CONCLUSION: Our findings support measurement of anti-infliximab antibodies only in the context of low infliximab concentrations <1 µg/mL. A higher therapeutic cut-off may be relevant in patients with negative antibodies. Further work is indicated to investigate the clinical significance of positive antibodies with therapeutic infliximab concentrations.


Assuntos
Anticorpos/sangue , Antirreumáticos/farmacocinética , Fármacos Gastrointestinais/farmacocinética , Infliximab/farmacocinética , Antirreumáticos/imunologia , Antirreumáticos/uso terapêutico , Artrite Reumatoide/sangue , Artrite Reumatoide/tratamento farmacológico , Monitoramento de Medicamentos , Feminino , Fármacos Gastrointestinais/imunologia , Fármacos Gastrointestinais/uso terapêutico , Humanos , Doenças Inflamatórias Intestinais/sangue , Doenças Inflamatórias Intestinais/tratamento farmacológico , Infliximab/imunologia , Infliximab/uso terapêutico , Masculino
4.
Ann Clin Biochem ; 47(Pt 3): 200-4, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20421310

RESUMO

BACKGROUND: Since more than 90% of cortisol is bound to protein, serum free cortisol (SFC) may be a more appropriate marker of adrenal status than total cortisol. However, measurement of SFC is technically difficult and calculated SFC may offer a more practical alternative. METHODS: SFC, measured by equilibrium dialysis coupled with immunoassay, and calculated using Coolens' equation from total cortisol and corticosteroid binding globulin (CBG) concentrations, was compared in short Synacthen test (SST) serum from 42 patients, of whom 20 demonstrated a suppressed adrenal response. RESULTS: Considering the patient group as a whole, calculated SFC was found to be significantly lower than measured SFC, pre- and post-Synacthen (P < 0.05 and <0.001, respectively). Upon classifying the patients as pass or fail based on total cortisol response to Synacthen, the difference in calculated and measured SFC only reached statistical significance for post-Synacthen concentrations in the pass group (P < 0.01), suggesting a greater discrepancy at higher cortisol concentrations. There was no difference in CBG levels between the pass and fail groups and both measured and calculated SFC gave a diminished 30 min response in subjects deemed to have failed the SST. CONCLUSION: Coolens' equation was found to underestimate measured SFC in this cohort of outpatients, as has been previously demonstrated, particularly in patients with a pronounced acute phase response. Although calculated SFC gave a diminished response in individuals deemed to have failed the SST, the concentration-dependent nature of the discrepancy may limit the usefulness of this method for assessing adrenal status.


Assuntos
Insuficiência Adrenal/diagnóstico , Hidrocortisona/análise , Modelos Teóricos , Idoso , Feminino , Humanos , Imunoensaio , Masculino , Pessoa de Meia-Idade , Transcortina/análise
5.
Anal Chem ; 78(9): 2948-56, 2006 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-16642980

RESUMO

This paper describes an application of Fourier transform (FT) voltammetry that provides a quantitative evaluation of the electron-transfer kinetics of protein molecules attached to electrode surfaces. The potential waveform applied in these experiments consists of a large-amplitude square wave of frequency f superimposed onto the traditional triangular voltage used in dc cyclic voltammetry. The resultant current-time response, when Fourier transformed into the frequency domain, provides patterns of data at the even harmonic frequencies that arise from nonlinearity in the Faradaic response. These even harmonic contributions are ideally suited for kinetic evaluation of electron-transfer processes because they are highly selective to quasi-reversible behavior (insensitive to reversible or irreversible processes) and almost devoid of background charging current. Inverse FT methods can then be used to provide the wave shapes of the dc as well as the ac voltammetric components and other characteristics employed to detect the level of nonideality present relative to theoretical models based upon noninteracting surface-confined molecules. The new form of data evaluation has been applied to the electron-transfer properties of a typical biological electron carrier, the blue copper protein azurin, immobilized on polycrystalline gold electrodes modified with self-assembled monolayers of different length alkanethiols. Details of the electrode kinetics (rates of electron transfer, dispersion, and charge-transfer coefficients) as a function of alkanethiol, apparent surface coverage, and capacitance are all deduced from the square wave (FT-inverse FT) protocol, and the implications of these findings are considered.


Assuntos
Azurina/química , Análise de Fourier , Capacitância Elétrica , Eletroquímica , Eletrodos , Ouro/química , Cinética , Membranas Artificiais , Sensibilidade e Especificidade , Propriedades de Superfície , Fatores de Tempo
6.
Chem Commun (Camb) ; (3): 316-7, 2004 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-14740055

RESUMO

A self-assembled monolayer (SAM), formed by the insitu saponification of a stilbenyl thioacetate on a gold electrode, yields fast electron transfer (ET)(the exchange rate at zero driving force exceeds 1600 s-1) with adsorbed molecules of the blue copper protein, azurin, over a distance exceeding 15 angstroms .


Assuntos
Proteínas de Bactérias/química , Estilbenos/química , Azurina/química , Eletroquímica , Eletrodos , Transporte de Elétrons , Estrutura Molecular
7.
FEBS Lett ; 539(1-3): 91-4, 2003 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-12650932

RESUMO

A periplasmic electron-transfer protein, cytochrome c(555)(m) from Aquifex aeolicus contains a 62-residue N-terminal extension by which it is anchored to the membrane--most probably via a thioester bond to its N-terminal cysteine. This linker can act as a "rope" to tether the protein close to its reaction partners. Mimicking this principle, a recombinant cytochrome c(555)(m), expressed in Escherichia coli, has been attached covalently to a gold electrode modified with 6-mercaptohexan-1-ol. The "tethered" cytochrome c(555)(m) displays remarkably fast electron-transfer kinetics, with an electrochemical exchange rate constant k(0) of 1.4 x 10(4) s(-1). The results show that fast electron transfer is associated with weak interactions: importantly, the tethered cytochrome can explore many different orientations without escaping into solution.


Assuntos
Proteínas de Bactérias/química , Grupo dos Citocromos c/química , Adsorção , Sequência de Aminoácidos , Bactérias , Eletrodos , Transporte de Elétrons , Escherichia coli , Dados de Sequência Molecular , Proteínas Recombinantes/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...